FRL Unit is so designed that it serves the function of the Filter, Regulator and the Lubricator in a compact space. The sintered filter with the water separator removes dirt, pipe scale, rust and condensate from the compressed air. The Regulator is a diaphragm-operated, relieving type regulator. The Regulator keeps the working pressure largely constant, irrespective of pressure fluctuations on the supply side.
The Lubricator is a mist-type.The required lubrication is set by the adjusting screw and the oil drops can be seen through the sight feed dome (drip cap). The amount of oil atomised is proportional to the air flow. With this unit, oil can be filled under pressure.
Basic Dimensions
All dimensions in mm unless otherwise specified
| Type | B1 | B2 | B3 | B4 | B5 | B6 | B7 | B8 | D1 BSP | D2 Dia. | D3 | D4 Dia. | D5 Dia. | D6 Dia. | H1 | H2 | H3 | H4 | L1 | L2 | L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FRL-200 | 104 | 98 | 40 | 98 | 77 | 40 | 2 | - - | 1/4" | 31 | M36 x 1.5P | 4.2 | 38 | 37 | 20 | 35 | 42 | 17.5 | 213.0 | 68.0 | 163 |
| FRL-800N | 140 | 125 | 59 | 118 | 99 | 46.5 | 3 | 55 | 1/2" | 49 | M52 x 1.5P | 5.5 | 53 | 52 | 32 | 60 | 69 | 30.0 | 280.5 | 97.5 | 205 |
| Specifications | FRL-200 | FRL-800 N |
|---|---|---|
| Medium | Compressed air | |
| Design | Sintered filter with water separator, Diaphragm regulator, Proportional lubricator | |
| Port size | 1/4" BSP | 1/2" BSP |
| Pressure gauge Port size | 1/8" BSP | 1/4" BSP |
| Mounting | Line mounting or mounting bracket | |
| Installation position | Vertical ±5° | |
| Standard nominal flow rate* | 1100 lit. / min. | 2600 lit. / min. |
| Maximum operating pressure | 16 bar | 16 bar |
| Regulator pressure range | 0.5 to 7 bar Standard
0.5 to 12 bar Standard Optional (0.2 - 2 bar, 0.2-4 bar) | |
| Temperature range | -10 °C to +60 °C | |
| Filter rating | 40 Microns Standard (Optional 1, 2, 5, 10, 20, 70, 100 µ) | |
| Condensate capacity (max) | 22 ml | 43 ml |
| Oil capacity | 45 ml | 110 ml |
| Range of lubricator operation | From 3 lit. / min. | From 6 lit. / min |
| Material | Housing and Connecting plates - Aluminium, Filter Bowl - Polycarbonate, Seal - Nitrile | |
- With 10 bar primary pressure, a working pressure of 6 bar, pressure drop of 1 bar.
- For correct lubricator operation, a minimum flow rate of 125 lit. / min. is required.
Note: Subject to change without prior notice