Air Pressure Regulators

For any kind of air-actuated equipment, there is usually a specific pressure which leads to the efficient operation of the equipment. At a higher pressure, the equipment will wear out excessively with no significant increase in the output and the compressed air will be wasted. Hence, while choosing an air pressure regulator, its features and flow rates must be carefully taken into account.

This diaphragm-operated, self-relieving type air pressure regulator, having a large flow capacity, maintains constant downstream air pressure inspite of fluctuations in the input pressure. The self-relieving feature of the regulator does not strain the downstream pipeline. The ergonomically designed pressure adjusting knob facilitates effortless operation of  the regulator. “The Push-to-Lock’ knob helps in locking the regulator at a predetermined or destred output air pressure.

All dimensions in mm unless otherwise specified

TypeB1B2B3B4B5B6B7B8D1 BSPD2 Dia.D3D4 Dia.D5 Dia.H1H2H3H4L1L2
REG-200645240987740.02--1/4" BSP31M36 × 1.5P4.23821354217.59668.0
REG-800 N8570571189946.53551/2" BSP49M52 × 1.5P5.55332606930.013297.5
SpecificationsREG-100 (Mini)REG-200 (Midi)REG-800 N (Midi)
MediumFiltered compressed air (Lubricated or Unlubricated)
DesignDiaphragm regulator self-relieving
MountingLine mounting, mounting bracket or in control panel
Port size1/4" BSP1/4" BSP1/2" BSP
Pressure gauge port size1/8" BSP1/8" BSP1/4" BSP
Installation PositionAnyAnyAny
Standard nominal flow rate1200 lit./min.1500 lit./min.3500 lit./min.
Maximum operating pressure10 bar16 bar16 bar
Regulating pressure0.5 to 7 bar 0.5 to 7 bar
0.5 to 12 bar
(Optional: 0.2–2 bar, 0.2–4 bar, 0.5–7 bar)
0.5 to 7 bar
0.5 to 12 bar
Temperature range-10 °C to +60 °C
MaterialHousing and connecting plates – Aluminium, Seal – Nitrile

*With 10 bar primary pressure, a working pressure of 6 bar, pressure drop of 1 bar

Note: Subject to change without prior notice

Note: Subject to change without prior notice

All dimensions in mm unless otherwise specified

Note: Subject to change without prior notice

Scroll to Top